Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.889
Filtrar
1.
Kyobu Geka ; 77(3): 217-221, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38465495

RESUMO

A 51-year-old man visited to our hospital because of chest discomfort and hematemesis. He was diagnosed with Mallory-Weiss syndrome and followed in outpatient clinic. One week later, he visited our hospital again for fever and discomfort. Chest computed tomography (CT) showed a foreign body perforated in the mediastinum in the upper esophagus, and he was urgently hospitalized for surgical removal of esophageal foreign body. Before surgery he vomited the esophageal foreign body with a lot of blood. Hematemesis was stopped spontaneously and contrast-enhanced CT revealed a pseudoaneurysm in the distal aortic arch, so thoracic endovascular aortic repair (TEVAR) was performed to prevent rupture. Esophageal endoscopy found that the site of esophageal injury healed spontaneously, so the patient was followed conservatively with antibiotics. He was discharged on postoperative day 18 uneventfully. TEVAR was an effective treatment for aortic injury caused by esophageal foreign body in our case.


Assuntos
Doenças da Aorta , Procedimentos Endovasculares , Corpos Estranhos , Masculino , Humanos , Pessoa de Meia-Idade , Hematemese/complicações , Esôfago/diagnóstico por imagem , Esôfago/cirurgia , Doenças da Aorta/cirurgia , Corpos Estranhos/complicações , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/cirurgia
2.
J Pediatr Gastroenterol Nutr ; 78(3): 601-607, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38305079

RESUMO

OBJECTIVES: Perforation of esophagus or stomach is a potential complication during and after insertion of a gastric tube in neonates. The aim of this study was to analyze different types of gastric tubes in a three-dimensional (3D) model of neonatal esophagus and stomach regarding potential perforations. METHODS: A 3D model of esophagus and stomach was created based on computed tomography data of a term neonate. Three types of gastric tubes were inserted into the 3D model, the localization was examined by radioscopy and the behavior, stiffness and manageability of each gastric tube was evaluated. RESULTS: Insertion of gastric tubes with higher stiffness was easier. The rates of correct localization differed significantly between the gastric tubes with the highest rate of correct localization in the softest tube (48.5%) and the lowest rate in the tube with the highest stiffness (21.2%). Additionally, the softest tube showed the lowest rate of localization of its tip at the stomach wall. CONCLUSIONS: The study illustrates differences between various types of gastric tubes regarding stiffness, behavior and resiliency. Softer gastric tubes may be beneficial. These differences may be relevant in neonatal care of very immature and very sick infants.


Assuntos
Esôfago , Estômago , Recém-Nascido , Lactente , Humanos , Estômago/diagnóstico por imagem , Esôfago/diagnóstico por imagem , Nutrição Enteral/métodos , Intubação Gastrointestinal/métodos
4.
Prague Med Rep ; 125(1): 47-55, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38380453

RESUMO

We present a case of a preterm neonate with a type IV laryngo-tracheo-oesophageal cleft, an uncommon congenital malformation, resulting from the failure of separation of the trachea and the oesophagus during fetal development, often associated with other deformities as well. Data in the literature shows that the long-term morbidity from the entity has declined over the last decades, even though prognosis remains unfavourable for types III and IV. This report emphasizes the complex issues neonatologists are faced with, when treating neonates with this rare disorder in the first days of life, what will raise suspicion of this rare medical entity, and that direct laryngoscopy/bronchoscopy finally depicts the exact extension of the medical condition. At the same time extensive evaluation for coexisting congenital anomalies should be performed. For all the above reasons, these neonates should be treated in specialized tertiary pediatric centers for multidisciplinary prompt management, which may improve, the outcome.


Assuntos
Anormalidades Congênitas , Laringe , Laringe/anormalidades , Recém-Nascido , Humanos , Criança , Laringe/diagnóstico por imagem , Laringe/cirurgia , Traqueia/diagnóstico por imagem , Traqueia/cirurgia , Traqueia/anormalidades , Esôfago/diagnóstico por imagem , Esôfago/cirurgia , Esôfago/anormalidades , Laringoscopia
5.
J Investig Med High Impact Case Rep ; 12: 23247096241231634, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38361358

RESUMO

Bilothorax, an exudative pleural effusion due to the accumulation of bile. It is also called cholethorax or thoracobilia and was initially reported in 1971. Here, we report a rare case of an elderly male presenting with bilateral bilothorax due to esophageal rupture. A 78-year-old man with multiple medical ailments presented to the emergency room (ER) with a severe episode of vomiting accompanied by a popping sound, respiratory distress, and right sided chest pain. The patient had tachycardia, BP of 101/89 mm Hg, and tachypnea. Computed tomography scan of the chest and abdomen revealed air adjacent to the esophagus, suggesting perforation, atelectasis of right lung, and bilateral pleural effusion (R > L). However, an esophagram did not reveal any perforation. Right-sided chest tube drained dark green bilious fluid. The day after admission, he experienced hemodynamic compromise and hypoxemia requiring intubation, along with fluids and inotropes support. Diagnosis of bilateral bilothorax complicated by hypoxemic respiratory failure with septic shock was made. Cultures were drawn, and empiric antibiotics were started. Nuclear hepatobiliary scan (HIDA) was performed to rule out a hepatobiliary fistula. Results showed reflux activity in the stomach, and distal esophageal leak was identified. Gastrojejunal stenting was performed. However, after prolonged intubation, the family decided on terminal extubation, and he died while receiving hospice care. This case highlights the rarity of bilateral bilothorax, where the HIDA scan played a crucial role in identifying an esophageal leak as the underlying cause, despite normal esophagram results. This condition necessitates prompt diagnosis and aggressive therapeutic interventions.


Assuntos
Iminoácidos , Derrame Pleural , Humanos , Masculino , Idoso , Derrame Pleural/etiologia , Esôfago/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Bile
7.
J Int Med Res ; 52(1): 3000605231224231, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38217419

RESUMO

Measuring patients' core body temperature during surgery is essential and commonly performed with an esophageal temperature probe. The probe must be placed in the lower third of the esophagus for accurate measurement. In this case report, we describe our experience of discovering an inadvertently malpositioned esophageal temperature probe in the right inferior lobar bronchus, which led to ventilation-related problems in a patient undergoing prostate surgery.


Assuntos
Laparoscopia , Neoplasias da Próstata , Robótica , Masculino , Humanos , Próstata , Temperatura Corporal , Temperatura , Prostatectomia/efeitos adversos , Esôfago/diagnóstico por imagem , Esôfago/cirurgia , Neoplasias da Próstata/cirurgia
12.
Int J Pediatr Otorhinolaryngol ; 176: 111803, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38043185

RESUMO

INTRODUCTION: Button batteries (BB) are a source of significant morbidity and mortality in young children. Little data is available regarding associations between esophageal impaction location and outcomes or need for surveillance imaging. METHODS: All patients treated at a single institution following BB ingestion between 2018 and 2022 were included for retrospective chart review. RESULTS: Twenty patients were treated at our institution BBs were located, or most significant damage observed, in the cervical esophagus (n = 10, 50 %), followed by thoracic esophagus (n = 6, 30 %), and abdominal esophagus (n = 4, 20 %). Patients with cervical esophageal impaction were younger (482 [370-866] days), than those with thoracic (1395 [871-2369] days) or abdominal esophageal impaction (2021.5 [1230.5-3419.5] days) (p = 0.003). Zargar Mucosal Injury Grade was significantly more severe in patients with cervical button battery impaction; 8/10 (80 %) had a ≥Grade IIIB injury, compared to 2/6 (33.3 %) thoracic impactions and 0/4 (0 %) abdominal impactions (p = 0.002). All patients who developed persistent esophageal stenosis (n = 6) had cervical battery impactions (6, 60 %, p = 0.015). Both TEFs (2/2) had anterior facing anode, while both (2/2) esophageal perforations had posterior. Only 1/20 (5 %) patients, and 1/7 (14.3 %) with serious complications, had a serious complication detected on routine, rather than clinically indicated follow-up surveillance. CONCLUSIONS: In our population, cervical BB impaction occurred more frequently in younger children, was associated with more severe mucosal injury, and had higher risk of stenosis. Nearly all complications were detected on clinically indicated rather than postoperative surveillance imaging.


Assuntos
Corpos Estranhos , Criança , Humanos , Pré-Escolar , Estudos Retrospectivos , Corpos Estranhos/complicações , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/cirurgia , Esôfago/diagnóstico por imagem , Esôfago/lesões , Fontes de Energia Elétrica , Ingestão de Alimentos
13.
Gastrointest Endosc ; 99(1): 108-115.e1, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37739237

RESUMO

BACKGROUND AND AIMS: Ultrathin EGD (UT-EGD) is an ideal tool for unsedated upper GI examination and pediatric gastroenterology but is rarely competent for EUS miniprobe (EUS-MP). We developed a UT-EGD US method (UT-EUS) and verified its clinical application value through animal experiments. METHODS: Five Bama miniature pigs were selected. Using an acoustic medium, we performed US on the duodenum, stomach, and esophagus, respectively, with conventional 20-MHz EUS miniprobe (EUS-MP-20), 20-MHz UT-EUS (UT-EUS-20), and 30-MHz UT-EUS (UT-EUS-30). The times to acquire 5 consecutive stable US images, number of identifiable wall layers, and quality and penetration depth of the images were recorded. RESULTS: No significant differences were found in the time required to obtain images between EUS-MP-20 and UT-EUS-20 at each site (P > .05). UT-EUS-30 showed more wall levels than UT-EUS-20 (P < .05). No significant differences were noted between EUS-MP-20 and UT-EUS-20 in imaging quality and penetration depth (P > .05). CONCLUSIONS: The UT-EUS is easy to use with a satisfactory image quality and has potential clinical application value.


Assuntos
Endoscopia do Sistema Digestório , Ultrassom , Humanos , Criança , Suínos , Animais , Endoscopia do Sistema Digestório/métodos , Endoscópios , Endossonografia/métodos , Esôfago/diagnóstico por imagem
18.
Neurogastroenterol Motil ; 35(12): e14692, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37845833

RESUMO

BACKGROUND AND AIMS: The distal contractile integral (DCI) quantifies the contractile vigor of primary peristalsis on high-resolution manometry (HRM), whereas no such metric exists for secondary peristalsis on functional lumen imaging probe (FLIP) panometry. This study aimed to evaluate novel FLIP metrics of contraction power and displaced volume in asymptomatic controls and a patient cohort. METHODS: Thirty-five asymptomatic controls and adult patients (with normal esophagogastric junction outflow/opening and without spasm) who completed HRM and FLIP panometry were included. The patient group also completed timed barium esophagram (TBE). Contraction power (estimate of esophageal work over time) and displaced volume (estimate of contraction-associated fluid flow) were computed from FLIP. HRM was analyzed per Chicago Classification v4.0. KEY RESULTS: In controls, median (5th-95th percentile) contraction power was 27 mW (10-44) and displaced volume was 43 mL (17-66). 95 patients were included: 72% with normal motility on HRM, 17% with ineffective esophageal motility (IEM), and 12% with absent contractility. Among patients, DCI was significantly correlated with both contraction power (rho = 0.499) and displaced volume (rho = 0.342); p values < 0.001. Both contraction power and displaced volume were greater in patients with normal motility versus IEM or absent contractility, complete versus incomplete bolus transit, and normal versus abnormal retention on TBE; p values < 0.02. CONCLUSIONS: FLIP panometry metrics of contraction power and displaced volume appeared to effectively quantify peristaltic vigor. These novel metrics may enhance evaluation of esophageal motility with FLIP panometry and provide a reliable surrogate to DCI on HRM.


Assuntos
Transtornos da Motilidade Esofágica , Peristaltismo , Adulto , Humanos , Esôfago/diagnóstico por imagem , Junção Esofagogástrica/diagnóstico por imagem , Contração Muscular , Manometria/métodos , Transtornos da Motilidade Esofágica/diagnóstico
19.
Pediatr Pulmonol ; 58(12): 3612-3614, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37701980

RESUMO

A 12-year-old adolescent boy presented with complaints of persisting dry cough and exertional dyspnea. A CT chest revealed a cystic lesion posterior to the trachea and a flexible bronchoscopy revealed extrinsic compression of the posterior trachea and partial obstruction of the left main bronchus. He underwent an Endoscopic Ultrasound with a Bronchoscope. A Hypoechoic cystic lesion was seen just in front of the esophagus. Fine needle aspiration yielded thick mucoid aspirate and cytology revealed ciliated columnar epithelium, confirming the diagnosis of a Bronchogenic cyst.


Assuntos
Cisto Broncogênico , Masculino , Humanos , Adolescente , Criança , Cisto Broncogênico/diagnóstico por imagem , Cisto Broncogênico/patologia , Broncoscópios , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Endossonografia , Esôfago/diagnóstico por imagem
20.
Am J Emerg Med ; 74: 14-16, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37734202

RESUMO

OBJECTIVE: Transesophageal echocardiography (TEE) is becoming increasingly utilized by emergency medicine providers during cardiac arrest. Intra-arrest, TEE confers several benefits including shorter pauses in chest compressions and direct visualization of cardiac compressions. Many ultrasound probe manufacturers recommend against performing defibrillation with the TEE probe in the mid-esophagus for fear of causing esophageal injury or damage to the probe, however no literature exists that has investigated this concern. To assess this, we performed cardiopulmonary resuscitation (CPR) and multiple defibrillations in 8 swine with a TEE probe in place. METHODS: We performed TEE on 8 adult swine during CPR and performed multiple 200 J defibrillations with the TEE probe in the mid-esophagus. Post-mortem, esophagi were dissected and inspected for evidence of injury. RESULTS: On macroscopic inspection of 8 esophagi, no evidence of hematoma, thermal injury, or perforation was noted. CONCLUSION: Our study suggests that performing defibrillation during CPR with a TEE probe in place in the mid-esophagus is likely safe and low risk for significant esophageal injury. This further bolsters the use of TEE in CPR and would enable continuous visualization of cardiac activity without the need to remove the TEE probe for defibrillation.


Assuntos
Traumatismos Abdominais , Reanimação Cardiopulmonar , Parada Cardíaca , Traumatismos Torácicos , Animais , Suínos , Reanimação Cardiopulmonar/efeitos adversos , Parada Cardíaca/etiologia , Parada Cardíaca/terapia , Ecocardiografia Transesofagiana , Esôfago/diagnóstico por imagem , Tórax
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...